RobotRisk Autonomous Systems Incident & Risk Register
RobotRiskSamsung SDI › 06 Feb 2020

Samsung SDI batteries implicated in South Korea government ESS fire probe

S3 · 06 Feb 2020 · Samsung SDI · ESS facility, South Jeolla Province, South Korea

Record

CompanySamsung SDI
IndustryEnergy storage
Type(s)regulatory
Date06 Feb 2020 (day precision)
Time of daynot documented
LocationESS facility, South Jeolla Province, South Korea
Severity (recall, enforcement, or fleet-wide fault)
Scalepart of a 27-fire national ESS incident cluster
Confidencehigh
Verified flagCited source on file; not independently re-verified

Summary

A South Korean government-led investigation into an Aug-Oct 2019 cluster of ESS fires found the state of charge of a Samsung SDI battery at a damaged South Jeolla Province facility had reached 95%, five points above the recommended threshold; the government attributed several of the fires to battery malfunction, which Samsung SDI disputed as unrelated to the fire cause.

Primary source

The Korea Times

Publisher: The Korea Times · Retrieved: 2026-09-16

Supporting source rows (1)
DateSupporting source rowPublisherLink
06 Feb 2020 Samsung SDI batteries implicated in South Korea government ESS fire probe The Korea Times The Korea Times

Energy storage context

regulatory context

Samsung SDI industry position

Related incidents

No related unique incidents are on file.

Other Samsung SDI entries